Extron IPL 250 IP Link Control Processor
Extron IPL 250
Product Code: IPL250
Buy Sell Sales Extron IPL 250

The IPL 250 is an Ethernet control processor for use as part of a TouchLink® configurable touchpanel control system. The IPL 250 provides vital AV system control capabilities including bidirectional serial ports, IR ports, relays, and contact closure inputs for interfacing with displays, switchers, sources, screen control, lighting systems, and other devices. The IPL 250 is configured using the free, easy-to-use Extron Global Configurator software. Using the Free GlobalViewer® Web-based AV resource management and remote control application, users can manage, monitor, and control both Extron and third-party equipment like projectors, plasmas, monitors, VCRs, DVD players, and other devices in an Ethernet network with the IPL 250.
• Ethernet monitoring and control — Manage, monitor, and control AV devices using a standard Ethernet network.
• Supports TouchLink® touchpanels
• Three bidirectional RS-232 serial ports for universal control of display devices, switchers, and other equipment — Provides simultaneous two-way control and monitoring of three serial devices.
• Four IR ports — Allows for one-way control of external devices that support IR such as DVD players.
• Four relays — Enables control of room functions such as lighting, screen settings, and other device functions.
• Four contact closure inputs — For interfacing with devices in a room such as sensors, switches, and relays.
• Supports Ethernet-controllable devices — Allows for control of up to six Ethernet-enabled AV devices such as displays, switchers, and sources.
• Easy to configure using Global Configurator — Global Configurator software makes product setup simple and intuitive – no programming knowledge is required.
• Extensive library of Extron Certified device drivers — Device drivers allow Extron products to control various display and source devices, such as projectors, flat-panel displays, and DVD players. Extron has produced thousands of fully tested and uniformly modeled Ethernet RS-232 and IR device drivers.
• Integrated IR Learner — Captures IR remote codes from a device’s handheld remote control.
• Integrated high performance Web server — Each IP Link control processor features a built-in Web server with memory available for storing device drivers, GlobalViewer, and custom user Web pages.
• Supports industry standard communications protocols — All IP Link models use industry standard communication protocols, including ARP, ICMP, IP, TCP, UDP, DHCP, HTTP, SMTP, and Telnet.
• E-mail notification enables proactive support — Technical support administrators and others can receive failure and service messages through an e-mail enabled cell phone, PDA, pager, or Internet e-mail account.
• Multiple levels of access with password protection — User access level authorizes limited entry to only pre-designated functions, while administrator access level permits full access to advanced settings.
• Free GlobalViewer®, Web-based AV resource management application — When used with GlobalViewer, IP Link control processors provide a powerful, flexible way to manage, monitor, and control both Extron and third-party equipment like projectors, plasmas, monitors, VCRs, DVD players, and other devices using a standard TCP/IP network.
• LED status indicators monitor activity of the device
• Internal real-time clock — Programmable operating alerts, sequencing, and automatic monitoring, together with the real-time clock and calendar, allow IP Link control processors to routinely check configured devices.
• Reset button
• Plenum rated - meets UL 2043 for heat and smoke release, excluding power supply.
• Highly reliable, energy-efficient external universal power supply included
Ethernet control interface
   Connectors  1 RJ-45 female connector
   Data rate  10/100Base-T, half/full duplex with autodetect
   Protocols  ARP, ICMP (ping), IP, TCP, UDP, DHCP, HTTP, SMTP, Telnet
   Default settings  Link speed and duplex level = autodetected
IP address = 192.168.254.254
Subnet mask = 255.255.0.0
Gateway = 0.0.0.0
DHCP = off
   Web server  Up to 200 simultaneous sessions
7.25 MB nonvolatile user memory
   Program control  Extron Global Configurator 3 for Windows®
Extron Simple Instruction Set (SIS)
Microsoft® Internet Explorer®, Telnet
   Global Viewer requirements  Microsoft® Internet Explorer® ver. 6 or higher
Serial control interface
   Quantity/type  3 bidirectional RS-232
   Connectors  (1) 3.5 mm captive screw connector, 5 pole
(2) 3.5 mm captive screw connectors, 3 pole
   Baud rate and protocol  300 to 115200 baud
Default settings (adjustable): 9600 baud, 8 data bits, 1 stop bit, no parity
    NOTE     The 5-pole port supports both hardware and software flow control.
The 3-pole ports support software flow control.
   Pin configurations   
      Serial, 5-pole captive screw  Pin 1 = Tx, 2 = Rx, 3 = GND, 4 = RTS, 5 = CTS
      Serial, 3-pole captive screw  Pin 1 = Tx, 2 = Rx, 3 = GND
IR control interface
   Quantity/type  4 IR (carrier and non-carrier)
   Connectors  (2) 3.5 mm captive screw connectors, 4 pole
   IR output carrier frequency  30 kHz to 1 MHz
   Pin configurations  Pins 1, 3, 5, 7 = IR signal ports 1, 2, 3, 4 (respectively)
Pins 2, 4, 6, 8 = GND
   IR learning carrier frequency  30 kHz to 1 MHz
   IR learning capture distance  2" (5.1 cm) to 12" (30.5 cm) from the front panel
Relay control interface
   Quantity/type  4 normally open relays
   Relay control connectors  (2) 3.5 mm captive screw connectors, 4 pole
   Relay control contact rating  24 V, 1 A
Contact closure control interface
   Quantity/type  4 contact closure inputs
   Contact input control connector  (1) 3.5 mm captive screw connector, 5 pole
   Contact closure (input only)   
      Input voltage range  0 to 5 VDC, clamped at +5.1 V
      Input impedance  10k ohms
      Threshold  1.6 VDC
   Pin configuration  Pins 1, 2, 3, 4 = inputs 1, 2, 3, 4; pin 5 = GND
General
   Power  Supplied by an included external power supply
   External power supply  100 VAC to 240 VAC, 50-60 Hz, external; to 12 VDC, 1 A, regulated
   Power input requirements  12 VDC, 0.5 A
   Temperature/humidity  Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
   Cooling  Convection, no vents
   Mounting   
      Rack mount  Yes, with optional 1U rack shelf
      Furniture mount  Under-furniture mountable with optional kit
      Projector mount  Yes, with optional projector mount kit
   Enclosure type  Metal
   Enclosure dimensions  1.7" H x 4.3" W x 3.0" D (1U high, quarter rack wide)
(4.3 cm H x 10.9 cm W x 7.6 cm D)
(Depth excludes connectors.)
   Product weight  0.7 lbs (0.3 kg)
   Shipping weight  2 lbs (1 kg)
   Vibration  ISTA 1A in carton (International Safe Transit Association)
   Regulatory compliance
      Safety  CE, c-UL, UL
UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release, excluding the power supply; meets UL 60950 for safety.
      EMI/EMC  CE, C-tick, FCC Class A, ICES, KC mark, VCCI
      Environmental  Complies with the appropriate requirements of RoHS, WEEE
   Warranty  3 years parts and labor
    NOTE     All nominal levels are at ±10%.
 
 

 