The Extron IPL T S1 is a compact
Ethernet control processor with a high performance Web server,
designed to integrate IP Internet Protocol connectivity into AV
systems. The IPL T S1 gives users the ability to remotely and
proactively monitor and troubleshoot a projector, flat-panel
display, switcher, or other serially controlled
device. |
• Ethernet
monitoring and control
• Supports TouchLink touchpanels
• Allows Web-based remote monitoring and remote control of AV
devices from any computer connected to a LAN, WAN, or the
Internet
• One bidirectional serial port supporting RS-232
communication — The IPL T S1 features one male 9-pin D-sub
serial connector that can communicate with one serially controlled
device.
• Integrated high performance Web server — Each IP Link
control processor features a built-in Web server with memory
available for storing device drivers, GlobalViewer, and custom user
Web pages.
• 7.25 MB of available flash memory
• Supports Ethernet-controllable devices — Allows for
control of up to six Ethernet-enabled AV devices such as displays,
switchers, and sources
• Low profile form factor — Housed in a 1" high,
quarter rack width metal enclosure.
• Supports industry standard communications protocols —
All IP Link models use industry standard communication protocols,
including ARP, ICMP, IP, TCP, UDP, DHCP, HTTP, SMTP, and
Telnet.
• Simultaneous multi-user support — Each IP Link device
supports multiple concurrent users, improving system
throughput.
• E-mail notification enables proactive support —
Technical support administrators and others can receive failure and
service messages through an e-mail enabled cell phone, PDA, pager,
or Internet e-mail account.
• Multiple levels of access with password protection —
User access level authorizes limited entry to only pre-designated
functions, while administrator access level permits full access to
advanced settings.
• Free GlobalViewer® Web-based AV resource management
application — When used with GlobalViewer® software, IP
Link control processors provide a powerful, flexible way to manage,
monitor, and control both Extron and third-party equipment like
projectors, plasmas, monitors, VCRs, DVD players, and other devices
using a standard TCP/IP network.
• Plenum rated - meets UL 2043 for heat and smoke release,
excluding power supply
• Highly reliable, energy-efficient external universal power
supply included |
Ethernet control interface |
Connectors |
1 female RJ-45 connector |
Data
rate |
10/100Base-T, half/full duplex with
autodetect |
Protocols |
ARP, ICMP (ping), IP, TCP, UDP, DHCP, HTTP, SMTP,
Telnet |
Default
settings |
Link speed and duplex level = autodetected
IP address = 192.168.254.254
Subnet mask = 255.255.0.0
Gateway = 0.0.0.0
DHCP = off |
Web
server |
Up to 200 simultaneous sessions
7.25 MB nonvolatile user memory |
Program
control |
Extron Global Configurator 3 for
Windows®
Extron Simple Instruction Set™
(SIS™)
Microsoft® Internet Explorer®,
Telnet |
Global Viewer
requirements |
Microsoft® Internet Explorer ver. 6 or
higher |
Serial control interface |
Quantity/type |
|
IPL T
S1 |
1 RS-232-only |
IPL T
S2 |
2 RS-232/RS-422/RS-485 configurable serial |
IPL T
S4 |
4 RS-232/RS-422/RS-485 configurable serial |
IPL T
S6 |
2 RS-232/RS-422/RS-485 configurable serial
4 RS-232-only |
Connectors |
|
IPL T
S1 |
1 male 9-pin D |
IPL T
S2 |
2 male 9-pin D and (1) 3.5 mm captive screw connector, 5
pole |
IPL T
S6 |
2 male 9-pin D and (1) 3.5 mm captive screw connector, 10
pole |
IPL T
S4 |
4 male 9-pin D |
Baud rate and
protocol |
300 to 115200 baud
Default settings (adjustable): 9600 baud, 8 data bits, 1 stop bit,
no parity |
Pin
configurations |
|
Serial,
9-pin D (IPL T S1) |
|
RS-232 |
2 = Rx, 3 = Tx, 5 = GND, 7 = RTS, 8 = CTS |
Serial,
9-pin D (IPL T S2, IPL T S4) |
|
RS-232
(default) |
2 = Rx, 3 = Tx, 5 = GND, 7 = RTS, 8 = CTS |
RS-422 |
2 = Rx-, 3 = Tx-, 5 = GND, 7 = Tx+, 8 =
Rx+ |
RS-485 |
2&3 (tied together) = data-, 5 = GND, 7&8 (tied
together) = data+ |
Serial,
5-pole captive screw |
|
IPL
T S2 |
COM1: pin 1 = Tx, 2 = Rx, 3 = GND
COM2: pin 4 = Tx, 5 = Rx, 3 = GND |
Serial,
10-pole captive screw |
|
IPL
T S6 |
COM3: pin 1 = Tx, 2 = Rx, 3 = GND
COM4: pin 4 = Tx, 5 = Rx, 3 = GND
COM5: pin 6 = Tx, 7 = Rx, 8 = GND
COM6: pin 9 = Tx, 10 = Rx, 8 = GND |
General |
Power |
Supplied by an included external power
supply |
External power
supply |
100 VAC to 240 VAC, 50-60 Hz, external; to 12 VDC, 1
A, regulated |
Power input
requirements |
12 VDC, 0.5 A |
Temperature/humidity |
Storage: -40 to +158 °F (-40 to +70 °C) / 10% to
90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%,
noncondensing |
Mounting |
|
Rack
mount |
Yes, with optional 1U rack shelf |
Furniture
mount |
Under-furniture mountable with optional
kit |
Pole
mount |
Yes, with optional pole mount kit |
Enclosure
type |
Metal |
Enclosure
dimensions |
|
IPL T
S1 |
1.0" H x 4.3" W x 3.0" D (quarter rack wide)
(2.5 cm H x 10.9 cm W x 7.6 cm D)
(Depth excludes connectors.) |
All
other models |
1.7" H x 4.3" W x 3.0" D (1U high, quarter rack wide)
(4.3 cm H x 10.9 cm W x 7.6 cm D)
(Depth excludes connectors.) |
Product
weight |
0.7 lbs (0.3 kg) |
Shipping
weight |
2 lbs (1 kg) |
Vibration |
ISTA 1A in carton (International Safe Transit
Association) |
Regulatory
compliance |
Safety |
CE, c-UL, UL
UL rated for use in plenum airspaces: meets UL 2043 for heat
and smoke release, excluding the power supply; meets UL 60950
for safety. |
EMI/EMC |
CE, C-tick, FCC Class A, ICES, VCCI |
Warranty |
3 years parts and labor |
NOTE |
All nominal levels are at
±10%. |
|
|
|
|
|