Extron IP T S6 Six Serial Port IP Link® Control Processor
Extron IPL T S6
Product Code: IPLTS6
Buy Sell Sales Extron IPL T S6

The Extron IPL T S6 is a compact control processor with a high performance Web server, designed to integrate IP Internet Protocol connectivity into AV systems. The IPL T S6 gives users the ability to remotely and proactively monitor and troubleshoot projectors, flat panel displays, switchers, and other serially controlled products.
• Ethernet monitoring and control
• Supports TouchLink touchpanels
• Two bidirectional RS-232/RS-422/RS-485 serial ports — The IPL T S6 features two 9-pin D-sub serial ports that can communicate with two RS-232, RS-422, and RS-485 serially controlled devices. When configured for pass-through mode, the IPL T S6 can pass through commands from an existing control system and control up to three devices.
• Four bidirectional RS-232 serial ports — The IPL T S6 features four captive screw serial ports that can control four RS-232 devices.
• Integrated high performance Web server — Each IP Link control processor features a built-in Web server with memory available for storing device drivers, GlobalViewer, and custom user Web pages.
• Supports Ethernet device drivers — Allows for control of up to six Ethernet-enabled AV devices such as displays, switchers, and sources
• Supports industry standard communications protocols — All IP Link models use industry standard communication protocols, including ARP, ICMP, IP, TCP, UDP, DHCP, HTTP, SMTP, and Telnet.
• Simultaneous multi-user support — Each IP Link device supports multiple concurrent users, improving system throughput.
• E-mail notification enables proactive support — Technical support administrators and others can receive failure and service messages through an e-mail enabled cell phone, PDA, pager, or Internet e-mail account.
• Multiple levels of access with password protection — User access level authorizes limited entry to only pre-designated functions, while administrator access level permits full access to advanced settings.
• Free GlobalViewer® Web-based AV resource management software — ◦Configurable - Global Configurator, a Windows® based configuration utility, makes product setup simple and intuitive – no programming knowledge is required.
◦ Extensive library of device drivers — Extron has produced thousands of fully tested and uniformly modeled RS-232 and IR device drivers. These drivers are completely finished modules, not just fragments of code; each one is a fully functioning driver file designed to be uploaded to an IP Link device with no programming skills required.
◦ Internal real-time clock - Programmable operating alerts, sequencing, and automatic monitoring together with the real-time clock and calendar allow IP Link control processors to routinely check configured devices.
• Plenum rated - meets UL 2043 for heat and smoke release, excluding power supply
• Highly reliable, energy-efficient external universal power supply included,
Ethernet control interface
   Connectors  1 female RJ-45 connector
   Data rate  10/100Base-T, half/full duplex with autodetect
   Protocols  ARP, ICMP (ping), IP, TCP, UDP, DHCP, HTTP, SMTP, Telnet
   Default settings  Link speed and duplex level = autodetected
IP address = 192.168.254.254
Subnet mask = 255.255.0.0
Gateway = 0.0.0.0
DHCP = off
   Web server  Up to 200 simultaneous sessions
7.25 MB nonvolatile user memory
   Program control  Extron Global Configurator 3 for Windows®
Extron Simple Instruction Set (SIS)
Microsoft® Internet Explorer®, Telnet
   Global Viewer requirements  Microsoft® Internet Explorer ver. 6 or higher
Serial control interface
   Quantity/type   
      IPL T S1  1 RS-232-only
      IPL T S2  2 RS-232/RS-422/RS-485 configurable serial
      IPL T S4  4 RS-232/RS-422/RS-485 configurable serial
      IPL T S6  2 RS-232/RS-422/RS-485 configurable serial
4 RS-232-only
   Connectors   
      IPL T S1  1 male 9-pin D
      IPL T S2  2 male 9-pin D and (1) 3.5 mm captive screw connector, 5 pole
      IPL T S6  2 male 9-pin D and (1) 3.5 mm captive screw connector, 10 pole
      IPL T S4  4 male 9-pin D
   Baud rate and protocol  300 to 115200 baud
Default settings (adjustable): 9600 baud, 8 data bits, 1 stop bit, no parity
   Pin configurations   
      Serial, 9-pin D (IPL T S1)   
         RS-232  2 = Rx, 3 = Tx, 5 = GND, 7 = RTS, 8 = CTS
      Serial, 9-pin D (IPL T S2, IPL T S4)   
         RS-232 (default)  2 = Rx, 3 = Tx, 5 = GND, 7 = RTS, 8 = CTS
         RS-422  2 = Rx-, 3 = Tx-, 5 = GND, 7 = Tx+, 8 = Rx+
         RS-485  2&3 (tied together) = data-, 5 = GND, 7&8 (tied together) = data+
      Serial, 5-pole captive screw   
         IPL T S2  COM1: pin 1 = Tx, 2 = Rx, 3 = GND
COM2: pin 4 = Tx, 5 = Rx, 3 = GND
      Serial, 10-pole captive screw   
         IPL T S6  COM3: pin 1 = Tx, 2 = Rx, 3 = GND
COM4: pin 4 = Tx, 5 = Rx, 3 = GND
COM5: pin 6 = Tx, 7 = Rx, 8 = GND
COM6: pin 9 = Tx, 10 = Rx, 8 = GND
General
   Power  Supplied by an included external power supply
   External power supply  100 VAC to 240 VAC, 50-60 Hz, external; to 12 VDC, 1 A, regulated
   Power input requirements  12 VDC, 0.5 A
   Temperature/humidity  Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
   Mounting   
      Rack mount  Yes, with optional 1U rack shelf
      Furniture mount  Under-furniture mountable with optional kit
      Pole mount  Yes, with optional pole mount kit
   Enclosure type  Metal
   Enclosure dimensions   
      IPL T S1  1.0" H x 4.3" W x 3.0" D (quarter rack wide)
(2.5 cm H x 10.9 cm W x 7.6 cm D)
(Depth excludes connectors.)
      All other models  1.7" H x 4.3" W x 3.0" D (1U high, quarter rack wide)
(4.3 cm H x 10.9 cm W x 7.6 cm D)
(Depth excludes connectors.)
   Product weight  0.7 lbs (0.3 kg)
   Shipping weight  2 lbs (1 kg)
   Vibration  ISTA 1A in carton (International Safe Transit Association)
   Regulatory compliance
      Safety  CE, c-UL, UL
UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release, excluding the power supply; meets UL 60950 for safety.
      EMI/EMC  CE, C-tick, FCC Class A, ICES, VCCI
   Warranty  3 years parts and labor
    NOTE     All nominal levels are at ±10%.
 
 

 