The Extron IPCP 505 is an IP
Link® control processor designed to support larger
configurable control systems. The IPCP 505 integrates Ethernet
connectivity into AV systems, giving users the ability to remotely
control, monitor, and troubleshoot AV equipment, including display
devices and switchers. With a high performance embedded Web server,
multiple bidirectional serial ports, relays, flex I/O ports, and an
Ethernet port, as well as four independently switched 12 VDC
outputs, this control processor is ideal for applications that
require control for multiple devices within a large-scale AV
system. Bidirectional ports provide simultaneous two-way control
and monitoring of serially controlled devices such as displays,
switchers, and other AV equipment. |
• Ethernet
monitoring and control — Manage, monitor, and control AV
devices using a standard Ethernet network.
• Supports TouchLink® touchpanels
• Eight bidirectional RS-232 serial ports for universal
control of display devices, switchers, and other AV equipment
— Provides simultaneous two-way control and monitoring of
eight serial devices.
• Eight one-way IR/Serial ports — Supports
unidirectional RS-232
• Eight relays for controlling room functions
• Four Flex I/O ports for interfacing with other systems in
the room
• Four independently switched 12 VDC outputs — Can be
controlled remotely.
• Supports Ethernet-controllable devices — Allows for
control of up to eight Ethernet-enabled AV devices such as
displays, switchers, and sources.
• Easy to configure using Global Configurator — Global
Configurator software makes product setup simple and intuitive
– no programming knowledge is required.
• Extensive library of Extron Certified device drivers
— Device drivers allow Extron products to control various
display and source devices, such as projectors, flat-panel
displays, and DVD players. Extron has produced thousands of fully
tested and uniformly modeled Ethernet, RS-232 and IR device
drivers.
• Integrated IR learner — Captures IR remote codes from
a device’s handheld remote control.
• Integrated high performance Web server — Each IP Link
control processor features a built-in Web server with memory
available for storing device drivers, GlobalViewer, and custom user
Web pages.
• Supports industry standard communications protocols —
All IP Link models use industry standard communication protocols,
including ARP, ICMP, IP, TCP, UDP, DHCP, HTTP, SMTP, and
Telnet.
• E-mail notification enables proactive support —
Technical support administrators and others can receive failure and
service messages through an e-mail enabled cell phone, PDA, pager,
or Internet e-mail account.
• Multiple levels of access with password protection —
User access level authorizes limited entry to only pre-designated
functions, while administrator access level permits full access to
advanced settings.
• Free GlobalViewer®, Web-based AV resource management
application — When used with GlobalViewer, IP Link control
processors provide a powerful, flexible way to manage, monitor, and
control both Extron and third-party equipment like projectors,
plasmas, monitors, VCRs, DVD players, and other devices using a
standard TCP/IP network.
• LED status indicators monitor activity of the device
• Internal real-time clock — Programmable operating
alerts, sequencing, and automatic monitoring, together with the
real-time clock and calendar, allow IP Link control processors to
routinely check configured devices.
• Reset button
• 1U, half rack width enclosure
• Highly reliable, energy-efficient internal universal power
supply |
Ethernet control interface |
Connectors |
1 RJ-45 female
connector |
Data
rate |
10/100Base-T, half/full duplex with
autodetect |
Protocols |
ARP, ICMP (ping), IP, TCP, UDP,
DHCP, HTTP, SMTP, Telnet |
Default
settings |
Link speed and duplex level =
autodetected
IP address = 192.168.254.254
Subnet mask = 255.255.0.0
Gateway = 0.0.0.0
DHCP = off |
Web
server |
Up to 200 simultaneous sessions
975 MB nonvolatile user memory |
Program
control |
Extron Global Configurator for
Windows®
Extron Simple Instruction Set (SIS™)
Microsoft® Internet Explorer®,
Telnet |
Global Viewer
requirements |
Microsoft® Internet
Explorer® ver. 6 or higher |
Serial control interface |
Quantity/type |
2 bidirectional RS-232, RS-422,
RS-485
6 bidirectional RS-232 |
Connectors |
(2) 3.5 mm captive screw connectors,
5 pole
(6) 3.5 mm captive screw connectors, 3 pole |
Baud rate and
protocol |
300 to 115200 baud (9600 baud =
default); 8 (default) or 7 data bits; 1 (default) or 2 stop
bits;
no parity (default), or even or odd parity |
NOTE |
The 5-pole ports support both hardware and
software flow control.
The 3-pole ports support software flow control. |
|
Pin
configurations |
|
Serial, 5-pole
captive screw |
RS-232
(default) |
Pin 1 = Tx, 2 = Rx, 3 = GND, 4 =
RTS, 5 = CTS |
RS-422 |
Pin 1 = Tx-, 2 = Rx-, 3 = GND, 4 =
Tx+, 5 = Rx+ |
RS-485 |
Pins 1 and 2 (tied together) =
data-, 3 = GND, 4 and 5 (tied together) = data+ |
Serial,
3-pole captive screw |
Pin 1 = Tx, 2 = Rx, 3 =
GND |
Flex I/O control interface |
Quantity/type |
4 analog input or digital
input/output (configurable) |
Connectors |
(1) 3.5 mm captive screw connector,
5 pole |
Digital
inputs |
|
Input
voltage range |
0 to 24 VDC, clamped at +30
VDC |
Input
impedance |
28k ohms |
Programmable
pullup |
2k ohms to +5 VDC |
Threshold
low to high |
Programmable range: 100 mV to 24
VDC, default = 2 VDC |
Threshold
high to low |
Programmable range: 100 mV to 24
VDC, default = 1 VDC |
Digital
outputs |
250 mA sink from 24 VDC
max. |
Analog
inputs |
12 bit A/D, 0 to 24
VDC |
Pin
configurations |
1, 2, 3, 4 = flex I/Os 1, 2, 3, 4; 5
= GND |
Control — IR/serial ports |
Quantity/type |
8 programmable: unidirectional
RS-232 (±5 V), or TTL level (0 to 5 V) infrared (carrier and
non-carrier) up to 1 MHz |
Connectors |
(4) 3.5 mm captive screw connectors,
4-pole |
Baud rate and protocol
(RS-232) |
300 to 115200 baud (9600 baud =
default); 8 (default) or 7 data bits; 1 (default) or 2 stop
bits;
no parity (default), or even or odd parity |
Pin
configurations |
For each port, pin
1 = signal, 2 = GND |
IR output carrier
frequency |
30 kHz to 1 MHz |
IR learning carrier
frequency |
30 kHz to 1 MHz |
IR learning capture
distance |
2" (5.1 cm) to 12" (30.5 cm) from
the front panel |
Relay control interface |
Quantity/type |
8 normally open
relays |
Relay control
connectors |
(4) 3.5 mm captive screw connectors,
4 pole |
Relay control contact
rating |
24 VDC, 1 A |
Switched DC power output |
Quantity/type |
4 switched 12 VDC
outputs |
Connectors |
(4) 3.5 mm captive screw connectors,
2 pole |
Power |
Maximum 40 watts
total |
Power
sense |
|
Range |
0.1 watt to 40 watts |
General |
Power
supply |
Internal
Input: 100-240 VAC, 50-60 Hz |
Power
consumption |
63.3 watts |
Temperature/humidity |
Storage: -40 to +158 °F (-40 to
+70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%,
noncondensing |
Cooling |
Convection, no vents |
Thermal
dissipation |
33.2 BTU/hr |
Mounting |
|
Rack
mount |
Yes, with optional 1U rack
shelf |
Enclosure
type |
Metal |
Enclosure
dimensions |
1.7" H x 8.7" W x 10.5" D (1U high,
half rack wide)
(4.3 cm H x 22.1 cm W x 26.7 cm D)
(Depth excludes connectors.) |
Product
weight |
2.5 lbs (1.1 kg) |
Shipping
weight |
5 lbs (3 kg) |
Vibration |
ISTA 1A in carton (International
Safe Transit Association) |
Regulatory
compliance |
Safety |
CE, c-UL, UL
Meets UL 60950 for safety. |
EMI/EMC |
CE, C-tick, FCC Class A, ICES, KC
mark, VCCI |
Environmental |
Complies with the appropriate
requirements of RoHS, WEEE |
Warranty |
3 years parts and
labor |
NOTE |
All nominal levels are at